The role of mean platelet volume as a predictor of postoperative shunt occlusion in children who underwent modified blalock-Taussig shunt surgery
نویسندگان
چکیده
منابع مشابه
False aneurysm following modified Blalock-Taussig shunt.
A nine month old infant with life threatening tracheal compression due to a Blalock-Taussig shunt aneurysm is described. Successful surgical management is discussed.
متن کاملPseudoaneurysm following modified Blalock Taussig shunt.
The modified Blalock-Taussig (BT) shunt is a common palliative procedure for congenital cyanotic heart disease (CHD) with diminished pulmonary blood flow(1). In developing countries, definitive surgery usually gets delayed due to limited resources and expertise(2). Children with cyanotic CHD and BT shunt often present to the pediatrician resulting in some of the complications of BT shunt being ...
متن کاملModified Blalock-taussig Shunt ----in- Hospital Shunt Occlusion: Experience at Nicvd
A modified Blalock-Taussig shunt (mBTS) is a surgically placed graft between the systemic and pulmonary arterial circulations that redirects systemic blood flow into the pulmonary circulation. It is often placed in those with rightsided obstructive cardiac defects to increase pulmonary blood flow. Postoperative shunt patency is critical to adequate systemic oxygenation. Nevertheless, in the imm...
متن کاملBlalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...
متن کاملBalloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence of proximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pamukkale Medical Journal
سال: 2017
ISSN: 1309-9833,1308-0865
DOI: 10.5505/ptd.2017.26056