The SoLid anti-neutrino detector's readout system
نویسندگان
چکیده
منابع مشابه
Future Atmospheric Neutrino Detectors
Future experiments focusing on atmospheric neutrino detection are reviewed. One of the main goals of these experiments is the detection of an unambiguous oscillation pattern (νμ reappearance) to prove the oscillation hypothesis. Further goals include the discrimination of νμ−ντ and νμ−νsterile oscillations, and the detection of a potential small νμ−νe contribution. The search for matter effects...
متن کاملHigh Rate Neutrino Detectors for Neutrino Factories
Three types of high rate neutrino detectors for neutrino interaction physics at neutrino factories are discussed. High performance general-purpose detectors might collect event samples on the order of a billion events or more. This could greatly improve on existing analyses of neutrino interactions and also lead to new and important analysis topics including, for example, precise determinations...
متن کاملDistributed readout detectors using superconducting tunnel junctions
Superconducting tunnel junctions (STJs) are able to measure the energy of single photons in the range from near infrared to X-rays. They provide simultaneous information of the impact time and wavelength of an absorbed photon. The main difficulty of these detectors compared with conventional imaging detectors lies in their limited pixel number. Each STJ has to be connected independently and the...
متن کاملCalibration of spiral-readout image-plate detectors
An improved method for intensity-uniformity calibration of diffraction data collected on spiral-readout image-plate (IP) systems is described. This technique is applicable to all types of spiral-readout IP detectors. The procedure utilizes an attenuated direct-beam scan of the IP to generate a radial-sensitivity calibration table. Exposure and scanning of the calibration frame are done on the s...
متن کاملAdvanced Readout ASICs for Multielement CZT Detectors
A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise pream...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2017
ISSN: 1748-0221
DOI: 10.1088/1748-0221/12/02/c02012