The T-Line TL-200 system for continuous noninvasive blood pressure measurement in medical ICU patients
نویسندگان
چکیده
منابع مشابه
An evaluation of the T-Line Tensymeter continuous noninvasive blood pressure device during induced hypotension.
A new continuous noninvasive blood pressure measurement device, the T-Line Tensymeter TL100 (Tensys Medical Inc., San Diego, CA, USA) which enables avoidance of arterial cannulation has been developed. We compared the values obtained using the T-Line values to simultaneous arterial line measurements in patients undergoing general anaesthesia with induced hypotension. Twenty-five patients, aged ...
متن کاملNoninvasive Blood Pressure Measurement Methods
This paper review the historical background of noninvasive blood pressure measurement methods with their accuracies achieved and explains the requirements for common national and international standards of accuracy. Also are shortly described the development of blood pressure measurement system and a method, named electronic palpation method (EP), suitable for the long-term measurement of heart...
متن کاملNoninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU
INTRODUCTION Noninvasive blood pressure (NIBP) monitoring methods are widely used in critically ill patients despite poor evidence of their accuracy. The erroneous interpretations of blood pressure (BP) may lead to clinical errors. OBJECTIVES To test the accuracy and reliability of aneroid (ABP) and oscillometric (OBP) devices compared to the invasive BP (IBP) monitoring in an ICU population....
متن کاملA Continuous Bedside Pressure Mapping System for Prevention of Pressure Ulcer Development in the Medical ICU: A Retrospective Analysis.
OBJECTIVE Patient repositioning to offload high-pressure areas is an essential component of pressure ulcer prevention for bed-bound patients. In most settings, the quantity and quality of offloading and repositioning are difficult to measure. Real-time continuous bedside pressure mapping (CBPM) offers an opportunity to do so. MATERIAL AND METHODS Data was collected on 627 patients being treat...
متن کاملContinuous blood pressure measurement with ultrasound.
Cardiovascular diseases are the main cause of death in Germany. A long-term blood pressure measurement is crucial to identify hypertension which can lead to cardiovascular disease. Conventional techniques use the automatic arm cuff method which is painful and provides only intermittent results. A new method for continuous measurement is developed using a DOPPLER ultrasound sensor on a superfici...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Critical Care
سال: 2012
ISSN: 1364-8535
DOI: 10.1186/cc10820