The visible absorption spectrum of water.
نویسندگان
چکیده
منابع مشابه
Visible and near-ultraviolet absorption spectrum of liquid water.
The optical absorption of pure liquid water in the 300-700-nm region has been measured by use of a long (1.5-m) path-length cell. The absorption spectrum coincides well with the edge of previous data in the 200-320-nm region and provides reliable data in the 320-420-nm region that has until now been a region of considerable unreliability. The data obtained for the 420-700-nm region agree quite ...
متن کاملWater dimer absorption of visible light
Laboratory measurements of water vapor absorption using cavity ring-down spectroscopy revealed a broad absorption at 405 nm with a quadratic dependence on water monomer concentration, a similar absorption with a linear component at 532 nm, and only linear absorption at 570 nm in the vicinity of water monomer peaks. D2O ab5 sorption is weaker and linear at 405 nm. Van’t Hoff plots constructed at...
متن کاملWater vapor absorption of visible and near infrared radiation.
Water vapor error function absorption coefficients for visible and near ir radiation have been recalculated from experimental transmission data. The error function absorption coefficients and the resulting transmissions as a function of precipitable water vapor are tabulated for wavelengths from 0.2 micro to 1.3 micro. Comparisons are made between computed and measured spectral transmittances.
متن کاملEffects of p-hydroxymercuribenzoate binding on the visible absorption spectrum of methemoglobin.
The binding of p-hydroxymercuribenzoate to human methemoglobin causes a perturbation of the visible heme abosrption spectrum which is expressed by an increase in absorbance in the high spin band regions, 480 to 510 nm and 590 to 640 nm, concomitant with a decrease in absorbance in the alpha- and beta-band absorption regions. The pH dependence of the p-hydroxymercuribenzoate-induced difference s...
متن کاملUltraviolet (250-550 nm) absorption spectrum of pure water.
Data for the spectral light absorption of pure water from 250 to 550 nm have been obtained using an integrating cavity made from a newly developed diffuse reflector with a very high UV reflectivity. The data provide the first scattering-independent measurements of absorption coefficients in the spectral gap between well-established literature values for the absorption coefficients in the visibl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Proceedings of the Japan Academy, Series B
سال: 1980
ISSN: 0386-2208,1349-2896
DOI: 10.2183/pjab.56.403