Calcium Optical Frequency Standardresearch at Ptb
At PTB we have developed an optical frequency standard based on laser cooled calcium atoms. A laser is frequencystabilized to the intercombination transition at a wavelength of 657 nm by means of time-domain atom interferences. The dependence of its frequency on various parameters was investigated by using different excitation schemes corresponding to phase sensitive and frequency sensitive ato...
متن کاملRecent Time and Frequency Activities at Ptb
Recent activities in the field of time and frequency metrology pursued at PTB are reviewed. Quasi-continuous operation of the cesium fountain frequency standard CSF1 enabled us to assess the performance of the older primary clocks CS1 and CS2 much better than previously possible. On average, the CSF1 and CS2 frequencies deviated by less than 5 parts in 10 during more than 2 years, which is well...
متن کاملAlternative Power Standard Realization at Radio Frequency
Modern ac-dc transfer equipments can operate up to 1 GHz at least. These equipments and the related ac-voltage measurements may be attractive for calibrating high frequency power sensors in term of ac-dc transfer difference instead of effective efficiency. Furthermore, below 30 MHz, the ac-voltage standard can be also used as powerful alternative and complement to the microcalorimeter technique...
متن کاملThe PTB Primary Standard for Electrical AC Power
The present PTB primary standard allows power measurements with a measurement uncertainty of about 2.5 μW / VA (k = 2). It operates at voltages up to 240 V and currents up to 10 A in the frequency range from 16 Hz up to some kHz. This paper gives a short overview of the working principle of the standard and recent improvements. © Metrology Society of India, All rights reserved. 1. Basic Operati...
متن کاملAbsolute frequency measurement of the neutral 40Ca optical frequency standard at 657 nm based on microkelvin atoms
We report an absolute frequency measurement of the optical clock transition at 657 nm in 40Ca with a relative uncertainty of 7.5 x 10-15 , one of the most accurate frequency measurements of a neutral atom optical transition to date. The frequency (455986240494135.8 ± 3.4) Hz was measured by stabilizing a diode laser system to a spectroscopic signal derived from an ensemble of 106 atoms cooled i...