Thermal decomposition of perchloric acid
نویسندگان
چکیده
منابع مشابه
Kinetics of Thermal Decomposition of Aqueous Perchloric Acid
Thermal decpmposition of 1.1-6.6 m aqueous perchloric acid at 295-322" yields oxygen, chlorine, and a small quantity of hydrochloric acid. The initial rates of decomposition have been measured, using a perchlorate ion activity electrode, and show 3.5 order dependence on the stoichiometric perchloric acid concentration; the corresponding rate coefficient and activation energy at 300.0" are 3.1 x...
متن کاملSolid–Solid Synthesis, Crystal Structure and Thermal Decomposition of Copper(II) Complex of 2-Picolinic Acid
The copper(II) complex [Cu(pic)2]·2H2O was synthesized with 2-picolinic acid (Hpic) and copper acetate as reactants by room temperature solid-solid reaction. The composition and structure of the complex was characterized by elemental analyses, single crystal X-ray diffraction, X-ray powder diffraction, FT-IR spectroscopy and thermogravimetry-differential scanning calor...
متن کاملSynthesis of CuO nanorods via thermal decomposition of copper-dipicolinic acid complex
Template-free CuO nanorods were synthesized through a three-step chemical method with no water-insoluble materials. The first step included the preparation of a Cu-complex, which was obtained from dipicolinic acid, L-lysine, and copper nitrate. Then, as the second step, the obtained solution was allowed to be relaxed for a week to and formation of some blue single-crystals single crystals, whic...
متن کاملSpectral Transmittance Characteristics of Holmium Oxide in Perchloric Acid Solution
Accepted: November 28, 1984 The work describes the methods and procedures used to determine the wavelengths of minimum transmittance of holmium oxide in perchloric acid solution. Measurements of spectral transmittance of the solutions were made by means of a high precision spectrophotometer over the wavelength range 200 nm to 680 nm. The wavelength scale accuracy of this instrument was verified...
متن کاملHYDROGEN ADSORPTION ON SILVER CATHODES IN PERCHLORIC ACID SOLUTIONS
In this paper studies of overvoltage and capacitance measurements at silver cathodes in aqueous perchloric acid at room temperature are described. Capacitances were deduced from open-circuit potential decay measurements. The increase of overvoltage and the growth of the measured capacitances in the course of electrolysis are attributed to a growing pseudocapacitance component. This is anal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Combustion and Flame
سال: 1971
ISSN: 0010-2180
DOI: 10.1016/s0010-2180(71)80056-1