Thermoluminescent and Monte Carlo dosimetry of IR06‐P103d brachytherapy source
This work presents experimental dosimetry results for a new 103Pd brachytherapy seed, in accordance with the AAPM TG-43U1 recommendation that all new low-energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermo...
متن کاملMonte Carlo dosimetry of a new 90Y brachytherapy source
PURPOSE In this study, we attempted to obtain full dosimetric data for a new (90)Y brachytherapy source developed by the College of Chemistry (Sichuan University) for use in high-dose-rate after-loading systems. MATERIAL AND METHODS The dosimetric data for this new source were used as required by the dose calculation formalisms proposed by the AAPM Task Group 60 and Task Group 149. The active...
متن کاملMonte Carlo dosimetric characterization of the IsoAid ADVANTAGE P103d brachytherapy source
For roughly 25 years, 125I and 103Pd sources have been used in the treatment of various malignant diseases such as prostate cancer. Various new sources have been marketed and produced to meet the demand for new sources to use in treatment. Recently, IsoAID LLC created the ADVANTAGE 103Pd source. Various dosimetric parameters must be determined to facilitate treatment planning using this source....
متن کاملDosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry
Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...
متن کاملdosimetric characterization of a high dose rate 192i source for brachytherapy application using monte carlo simulation and benchmarking with thermoluminescent dosimetry
background: the purpose of this project was to derive the brachytherapy dosimetric functions described by american association of physicists in medicine (aapm) tg-43 u1 based on high dose rate 192i sources. materials and methods: the method utilized included both simulation of the designed polymethyl methacrylate (pmma) phantom using the monte carlo of mcnp4c and benchmarking of the simulation ...