Thermoluminescent dosimetry in clinical kilovoltage beams

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in kilovoltage x-ray beam dosimetry.

This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage...

متن کامل

Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry

The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical alg...

متن کامل

Tandem Study with Thermoluminescent Materials in Standard Diagnostic Beams

Tandem systems formed with different thermoluminescent dosemeters were evaluated in standard diagnostic radiation beams. The utilized materials are commercially available, and the aim of this study was to carry out a performance comparison. The results show that the energy dependence of the materials, except TLD-100, were very high. Therefore, there are several possibilities of pair combination...

متن کامل

Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms.

The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA p...

متن کامل

Thermoluminescent Detectors for Neutron Dosimetry at High Altitudes

At high altitudes in the Earth’s atmosphere cosmic-ray induced neutrons become the dominant contributors to the biologically relevant dose equivalent. Depending on the geomagnetic latitude and the solar activity cycle, neutron dose onboard aircraft amounts to about 50 to 70 % of the overall dose equivalent. Neutron detection in complexly mixed radiation environments by means of active, i.e. pow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiography

سال: 2013

ISSN: 1078-8174

DOI: 10.1016/j.radi.2013.07.001