Three-dimensional Bioluminescence Tomography based on Bayesian approach
نویسندگان
چکیده
منابع مشابه
Source-detector calibration in three-dimensional Bayesian optical diffusion tomography.
Optical diffusion tomography is a method for reconstructing three-dimensional optical properties from light that passes through a highly scattering medium. Computing reconstructions from such data requires the solution of a nonlinear inverse problem. The situation is further complicated by the fact that while reconstruction algorithms typically assume exact knowledge of the optical source and d...
متن کاملThree-dimensional Bayesian optical diffusion tomography with experimental data.
Reconstructions of a three-dimensional absorber embedded in a scattering medium by use of frequency domain measurements of the transmitted light in a single source-detector plane are presented. The reconstruction algorithm uses Bayesian regularization and iterative coordinate descent optimization, and it incorporates estimation of the detector noise level, the source-detector coupling coefficie...
متن کاملThree-dimensional photoacoustic tomography based on the focal-line concept.
A full ring ultrasonic array-based photoacoustic tomography system was recently developed for small animal brain imaging. The 512-element array is cylindrically focused in the elevational direction, and can acquire a two-dimensional (2D) image in 1.6 s. In this letter, we demonstrate the three-dimensional (3D) imaging capability of this system. A novel 3D reconstruction algorithm was developed ...
متن کاملThree Dimensional Tomography
A series expansion method in three dimensional tomography is presented. While the function to be reconstructed is expanded in terms of spherical harmonics and orthogonal polynomials, the projection of the function is expanded in terms of Euler angles in the angular part and orthogonal polynomials in the radial part. The computer simulation of the reconstruction demonstrates the applicability of...
متن کاملNumerical approximation of bioluminescence tomography based on a new formulation
Bioluminescence tomography (BLT) is a promising new method in biomedical imaging. The BLT problem is an ill-posed inverse source problem, usually studied through a regularization technique. A new approach is proposed for solving the BLT problem based on an adjoint equation. Numerical examples show that the new formulation allows us to obtain accurate solutions.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2009
ISSN: 1094-4087
DOI: 10.1364/oe.17.016834