Thrombi Produced in Stagnation Point Flows Have a Core–Shell Structure
نویسندگان
چکیده
منابع مشابه
Instabilities in stagnation point flows of polymer solutions
A recently-developed microfluidic device, the optimized shape cross-slot extensional rheometer, or OSCER [S.J. Haward, M.S.N. Oliveira, M.A. Alves and G.H. McKinley, Phys. Rev. Lett. 109, 128301 (2012)], is used to investigate the stability of viscoelastic polymer solutions in an idealized planar stagnation point flow. Aqueous polymer solutions, consisting of poly(ethylene oxide) and of hyaluro...
متن کاملLarge-eddy simulations of turbulent reacting stagnation point flows
A methodology for solving unsteady premixed turbulent flame propagation problems in high Reynolds number (Re), high Damkohler number (Da) spatially evolving flows is developed. The method is based on Large-Eddy Simulation (LES) with a subgrid combustion model based on the Linear-Eddy Model (Kerstein, 1991). An inter-LES cell burning mechanism has been added to the present formulation to account...
متن کاملRichardson's pair diffusion and the stagnation point structure of turbulence.
DNS and laboratory experiments show that the spatial distribution of straining stagnation points in homogeneous isotropic 3D turbulence has a fractal structure with dimension D(s)=2. In kinematic simulations the exponent gamma in Richardson's law and the fractal dimension D(s) are related by gamma=6/D(s). The Richardson constant is found to be an increasing function of the number density of str...
متن کاملOscillatory Flow Near a Stagnation Point
The classical Hiemenz solution describes incompressible two-dimensional stagnation point flow at a solid wall. We consider an unsteady version of this problem, examining particularly the response close to the wall when the solution at infinity is modulated in time by a periodic factor of specified amplitude and frequency. While this problem has already been tackled in the literature for general...
متن کاملSurface Reaction Near a Stagnation Point
To measure rate constants while performing biomolecular interaction analysis (BIA), scientists often use resonant mirror devices such as the IAsysTM. A full mathematical model of the IAsysTM consists of a convection–diffusion equation in a closed well with a reacting surface at the bottom. The flow in the well is complex, but near the sensor, the qualitative nature of the reaction can be analyz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cellular and Molecular Bioengineering
سال: 2017
ISSN: 1865-5025,1865-5033
DOI: 10.1007/s12195-017-0503-x