Thyristor-Controlled AC Reactor Based Fault Current Limiter for Distribution Network Stability Enhancement
نویسندگان
چکیده
منابع مشابه
Application of thyristor-controlled series reactor for fault current limitation and power system stability enhancement
Various types of Fault Current Limiters (FCLs) have been proposed and proven to offer numerous advantages with respect to transmission losses, voltage quality, and power system stability. However, FCL research has largely focused on only the FCL system, including optimization of components, efficiency improvement, and cost reduction. Conventional solutions to fault current problems, such as spl...
متن کاملStudy of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملVoltage Stability Limit Enhancement using Thyristor Controlled Series Capacitor (TCSC)
Flexible Alternating Current Transmission System (FACTS) devices can regulate the active and reactive power control as well as adaptive to voltage magnitude control simultaneously, because of their flexibility and fast control characteristics. Placement of these devices in suitable location can lead to control in line flow and maintain bus voltages in desired level and so improve voltage stabil...
متن کاملRETRACTED! Transient stability enhancement of DFIG based 10 MW wind farm by using of new inductive bridge type fault current limiter
RETRACTED
متن کاملTransient stability enhancement of DFIG based 10 MW wind farm by using of new inductive bridge type fault current limiter
Due to numerous advantages of the doubly-fed induction generator (DFIG), the application of DFIG based wind generator (WG) is increasing very rapidly. However, the transient stability is one of the major concerns of the DFIG based wind generator. Therefore to accomplish this goal, in this paper, an existing non-linear controller based new inductive bridge type fault current limiter (NC-NIBFCL) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electrical Engineering and Technology
سال: 2016
ISSN: 1975-0102
DOI: 10.5370/jeet.2016.11.5.1070