Tibial Tunnel Cyst Formation after Anterior Cruciate Ligament Reconstruction Using a Non-Bioabsorbable Interference Screw

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recurrent Tibial Tunnel Cyst Formation Following Anterior Cruciate Ligament Reconstruction and Interference Screw Removal

A unique case of a collegiate athlete who suffered an anterior cruciate ligament injury leading to the formation of a synovial cyst is described. The cyst, localized over the tibial tunnel, resulted from irritation caused by the removal of interference screws. The anterior cruciate ligament (ACL) is one of the four major ligaments of the knee and is regarded as the most critical stabilizer. The...

متن کامل

Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL) Reconstruction using a Semitendinosus-gracilis Graft: A Case Report.

ABSTRACT When a patient presents with knee pain and locking after an anterior cruciate ligament (ACL) reconstruction, a new meniscal injury or an osteochondral loose body are usually considered for differential diagnosis. We present the case of a 22-year-old female with just these complaints 6 months after ACL reconstruction surgery. Magnetic resonance imaging (MRI) of the knee showed a broken ...

متن کامل

Painful pretibial pseudocyst at bioabsorbable interference screw aperture two years after anterior cruciate ligament reconstruction.

We report the case of a patient with a painful subcutaneous nodule, measuring 13 mm × 17 mm, at the pretibial graft aperture site, which presented two years after a successful anterior cruciate ligament reconstruction with an autologous hamstring graft. A bioabsorbable poly-L-lactide interference screw was used for graft fixation at the tibial aperture. The patient underwent surgical excision o...

متن کامل

Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?

BACKGROUND Approximately 100,000 anterior cruciate ligament (ACL) reconstructions are performed in the USA each year. Interference screw fixation is considered the standard for rigid fixation of the graft and provides higher fixation strength compared with other devices such as staples or buttons. The present study summarizes the latest evidence comparing the effectiveness of the available clas...

متن کامل

Interference Screw Cruciate Divergence in Endoscopic Anterior Ligament Reconstruction

Interference screws are commonly used for graft fixation in bonetendon-bone patellar tendon anterior cmciate ligament (ACL) reconstruction. The clinical significance of graft screw divergence has not been well studied. This report retrospectively reviews our initial experience in 73 consecutive endoscopic (single-incision) ACL reconstructions using interference screw fixation. Femoral divergenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Knee Surgery & Related Research

سال: 2015

ISSN: 2234-0726,2234-2451

DOI: 10.5792/ksrr.2015.27.4.269