Tip Apex Distance: a useful method to assess extra-capsular neck of femur fixation?
نویسندگان
چکیده
منابع مشابه
Tip Apex Distance: a useful method to assess extra-capsular neck of femur fixation?
The Tip Apex Distance (TAD) is a simple measurement that predicts screw cut-out in the femoral head from trochanteric fractures treated with a fixed angle sliding hip screw device [1]. It uses a numerical value to show placement of the screw in the head: higher values indicating higher likelihood of fixation failure by extrusion of the screw. Currently the cost of hip fracture care in the UK is...
متن کاملAwareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip.
We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and late...
متن کاملFailure of PFNA: helical blade perforation and tip-apex distance.
Since the clinical introduction of proximal femoral nail antirotation (PFNA) by AO group in 2004 and PFNA-II (Asian version) in 2008, this type of cephalomedullary nail with single head-neck helical blade were commonly used in unstable pertrochanteric and intertrochanteric fractures in geriatric patients. Recently, severe complications of helical blade perforation through the femoral head, into...
متن کاملA new device to treat intra-capsular fracture neck of femur non-union
In adolescents and young adults, femoral neck fractures often result from high-velocity trauma. These fractures are usually of vertical shear pattern. There is an increased incidence of avascular necrosis and non-union, which is difficult to treat. Non-union of fractured neck of femur in young adults is a serious problem. There is growing evidence that these fractures should be treated with an ...
متن کاملA new method of perfusion fixation for the rabbit femur.
We report a new method of perfusion fixation for the proximal one-third of the femur of the Japanese white rabbit. Fluids to flush the blood and fix the marrow were injected into the abdominal aorta and drained from the stump of the femur. The oozing of the fluids from the stumps guaranteed complete flushing and fixation. The new method facilitated fixation and decreased the volume of necessary...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Trauma & Treatment
سال: 2012
ISSN: 2167-1222