Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry
نویسندگان
چکیده
منابع مشابه
Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry
AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and OR...
متن کاملGoldmann applanation tonometry versus ocular response analyzer for intraocular pressure measurements in keratoconic eyes.
PURPOSE To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) in patients with keratoconus (KC) and analyze their dependence on ocular anatomic parameters. METHODS Patients with KC were recruited prospectively. IOP was measured using GAT and ORA. The ORA provided a Goldmann correlated IOP (IOPg) and a c...
متن کاملOcular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements.
PURPOSE To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central cornea...
متن کاملAssessment of intraocular pressure measured by Reichert Ocular Response Analyzer, Goldmann Applanation Tonometry, and Dynamic Contour Tonometry in healthy individuals.
AIM To investigate the accuracy of intraocular pressure (IOP) as measured by a Reichert Ocular Response Analyzer (ORA), as well as the relationship between central corneal thickness (CCT) and IOP as measured by ORA, Goldmann applanation tonometry (GAT), and dynamic contour tonometry (DCT). METHODS A total of 158 healthy individuals (296 eyes) were chosen randomly for measurement of IOP. After...
متن کاملA comparison of the NCT Reichert R7 with Goldmann applanation tonometry and the Reichert ocular response analyzer.
PURPOSE The aim of this study was to evaluate the accuracy of intraocular pressure (IOP) values from the new non-contact tonometer (NCT) Reichert R7 by comparing results with those from Goldmann applanation tonometry (GAT) and the Reichert Ocular Response Analyzer (ORA). Other ocular dimensions were assessed to evaluate their potential influence on the IOP values obtained. METHODS Ninety two ...