Tooth Preparation with a 9.3 µm CO2 Laser Reduces Demineralization around Dental Restorations
نویسندگان
چکیده
منابع مشابه
Effect of a CO2 Laser on the Inhibition of Root Surface Caries Adjacent to Restorations of Glass Ionomer Cement or Composite Resin: An In Vitro Study
This study investigated the effect of CO2 laser irradiation on the inhibition of secondary caries on root surfaces adjacent to glass ionomer cement (GIC) or composite resin (CR) restorations. 40 dental blocks were divided into 4 groups: G1 (negative control): cavity preparation + adhesive restoration with CR; G2: (positive control) cavity preparation + GIC restoration; G3: equal to group 1 + CO...
متن کاملRectifying the Tooth Preparation Errors in All-Ceramic Restorations
All-ceramic restorations have been used for long as restorative material in dentistry. However, the recent advances in both the material and technology of all-ceramic have made them a more viable treatment option. Several practitioners hesitate in giving this option to patient for fear of failure. This article describes all the failures of all-ceramic material and how to prevent them. In partic...
متن کاملDeffects in Dental Alloys Cast Single Tooth Restorations
Casting failures of alloys in dental technology should be the exception, not the rule. They have to be detected in time and associated with possible causes. For the experimental part base metal alloys single tooth restorations were achieved using the conventional lost wax process for casting in order to be evaluated. Some casting defects obtained during the experimental part are exemplified: in...
متن کاملMode-locked Tm,Ho:YAP laser around 2.1 μm.
A passively mode-locked Tm,Ho:YAP laser around 2.1 μm wavelength employing a semiconductor saturable absorber mirror is demonstrated. Stable continuous wave mode-locking operation was achieved at variable center wavelengths of 2036.5 nm, 2064.5 nm, 2095.5 nm, 2103.5 nm, and 2130 nm, respectively. Pulses as short as 40.4 ps were obtained at 2064.5 nm with a spectral FWHM of 0.5 nm at output powe...
متن کاملEfficient diode-pumped laser operation of Tm:Lu2O3 around 2 μm.
We report on the first diode-pumped laser operation of thulium-doped Lu2O3. With a very compact setup an output power of 75 W and slope efficiencies of around 40% with respect to the incident pump power were achieved at room temperature. Free running laser operation was observed at wavelengths of 2065 nm and 1965 nm. With a birefringent filter the wavelength could continuously be tuned from 192...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Open Access Journal of Dental Sciences
سال: 2020
ISSN: 2573-8771
DOI: 10.23880/oajds-16000259