Trace Voltammetric Determination of Lead at a Recycled Battery Carbon Rod Electrode

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltammetric determination of cysteine at a carbon paste electrode modified with Cu(II)-salen complex

The electrochemical behavior of a modified carbon paste electrode (MCPE) with N,N′ethylenbis(salicylideneiminato)copper(II) complex ([Cu(II)-Salen]) was investigated as a newsensor for cystein. The Britton-Robinson buffer with pH 5, 10% modifier in electrode, potentialscanning rate of 20 mVs-1 and puls height of 50 mV were used as the optimum condition for thedetermination of cysteine using car...

متن کامل

Voltammetric Determination of Chloramphenicol at Electrochemically Pretreated Glassy Carbon Electrode

A sensitive square wave voltammetric method for the determination of chloramphenicol (CAP) was developed using electrochemically pretreated glassy carbon electrode (EPGCE). Electrochemical pretreatment of the electrode greatly enhanced the reduction peak current (Ip) of CAP. The electrochemical investigation of CAP was carried out by using cyclic and square wave voltammetry techniques. CAP show...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

voltammetric determination of cysteine at a carbon paste electrode modified with cu(ii)-salen complex

the electrochemical behavior of a modified carbon paste electrode (mcpe) with n,n′ethylenbis(salicylideneiminato)copper(ii) complex ([cu(ii)-salen]) was investigated as a newsensor for cystein. the britton-robinson buffer with ph 5, 10% modifier in electrode, potentialscanning rate of 20 mvs-1 and puls height of 50 mv were used as the optimum condition for thedetermination of cysteine using car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2019

ISSN: 1424-8220

DOI: 10.3390/s19040770