Transcatheter closure of aortopulmonary window with Amplatzer duct occluder II

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of aortopulmonary window with Amplatzer duct occluder II

Sir, An aortopulmonary window (APW) is a rare cardiac malformation, first reported by Elliotson, is found in 0.1% of patients with congenital cardiac lesions.[1] In most cases, surgical repair is undertaken during infancy although isolated cases have been reported of transcatheter device closures. We report our experience of transcatheter APW closure via antegrade and retrograde methods using a...

متن کامل

Transcatheter closure of patent arterial duct with amplatzer duct occluder II additional sizes in children.

Amplatzer duct occluder II additional sizes is a new generation of device for arterial duct closure, appropriate for infants and older children. We report the successful transcatheter closure of the arterial duct in an infant and two older children with the above-mentioned device.

متن کامل

Transcatheter closure of coronary artery fistula with an Amplatzer Duct Occluder II in a symptomatic infant.

induced platelet aggregation (8), others documented increased aggregation of platelets in the presence of THC (9). Increased myocardial oxygen demand, decreased blood supply, marked vasoconstriction of the coronary arteries and platelet activation all contribute to the development of acute event. In our case, probably, he has had early onset coronary heart disease in whom the cigarette smoking ...

متن کامل

Transcatheter closure of postsurgical ruptured sinus of Valsalva with Amplatzer Duct Occluder II AS™ device

Sinus of Valsalva (SV) rupture is a rare, cardiac complication after surgical repair of complex congenital heart disease. This paper reports a 4-year-old male child with double outlet right ventricle (RV) and pulmonary stenosis with superior-inferior arrangement of the ventricles, who was submitted to surgical repair using the "reparation a l'etage ventriculaire" procedure. A few months after a...

متن کامل

Transcatheter closure of left coronary cameral fistula with Amplatzer duct occluder II.

The surgical and transcatheter coil closure of coronary arterial fistulas are described in the literature. We report our experience with the successful transcatheter closure of a coronary arterial fistula, arising from the left coronary artery and draining into the right ventricle, with the new Amplatzer duct occluder II device.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of Pediatric Cardiology

سال: 2017

ISSN: 0974-2069

DOI: 10.4103/0974-2069.197060