[Transcatheter aortic valve-in-valve implantation for failed aortic bioprosthesis].

Percutaneous valve replacement for severe aortic stenosis has been shown to be an alternative treatment option for high surgical risk patients. We describe our first valve-in-valve procedure in a patient with a degenerated aortic bioprosthesis and severe regurgitation.

متن کامل

Transcatheter transapical valve-in-valve implantation for degenerated mitral bioprosthesis

A 76-year-old woman with a history of aortic and mitral valve (Mosaic 19 mm; Hancock II 25 mm bioprosthesis, Medtronic Inc., Minneapolis, Minnesota) replacement and former coronary artery bypass grafting in 2010 (left internal mammary artery-left anterior descending artery (LIMA-LAD), aorta-obtuse marginal coronary artery (Ao-OM)) was admitted to our hospital with recurrent pulmonary edema. Her...

متن کامل

Failed valve-in-valve transcatheter mitral valve implantation.

A 73-year old man underwent trans-septal anterograde implantation of a 26-mm Sapien-XT valve (Edwards Lifesciences, CA, USA) to treat a degenerated 27-mm Carpentier-Edwards bioprosthesis. During the follow-up, the patient experienced severe haemolysis with moderate-to-severe inter-valvular leak, and fluoroscopy revealed possible incomplete apposition of the Sapien-XT (Fig. 1). Reoperation was p...

متن کامل

Failed valve-in-valve transcatheter aortic valve implantation.

c 2 a k o f d t 0 In 2004, a 68-year-old man received aortocoronary bypass surgery and a 23-mm Hancock porcine bioprosthesis (Medtronic, Minneapolis, Minnesota). Six years later, in January 2011, cardiac re-evaluation was performed due to progressive dyspnea. Invasive angiography showed open bypass grafts and severe stenosis of the porcine aortic bioprosthesis. Due to significant comorbidities,...

متن کامل

Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves.

BACKGROUND The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative. ...