Transient and steady state estimation of human oxygen uptake based on noninvasive portable sensor measurements

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steady-state measurements of respiration rate with an oxygen electrode.

The respirometer is shown in Fig. 1. The cathode was made from gold wire of 0.51 mm diam which was coated with glass of low melting point (4). After mounting the cathode as shown in Fig. 1, the gold and its glass coating were ground to a flat surface and polished using a series of carborundum grinding powders. The cathode was maintained at -0.45 V with respect to the calomel electrode. The elec...

متن کامل

Multi-Area State Estimation Based on PMU Measurements in Distribution Networks

State estimation in the energy management center of active distribution networks has attracted many attentions. Considering an increase in complexity and real-time management of active distribution networks and knowing the network information at each time instant are necessary. This article presents a two-step multi-area state estimation method in balanced active distribution networks. The prop...

متن کامل

Steady-state quantile estimation

Steady state simulation is used to study long-run behavior. Usually only the expected value of the steady state probability distribution function is estimated. In many cases quantiles of this distribution are of higher interest. In this paper a new usage of quantile estimators is proposed, which is derived from mean value analysis and is based on multiple independent replications. The advantage...

متن کامل

Steady State and Transient Oscillations in NH, Oxidation on Ptl

Sustained oscillations of catalyst temperature have been observed in NH, oxidation on Pt wires and foils in a l-atm flow reactor. Simple and complex oscillations with periods from ~1 set to several minutes were obtained for gas compositions between 20 and 40% NH3 in air. These depend sensitively on gas composition, flow velocity, and geometry. Oscillatory behavior is quite stable over short tim...

متن کامل

Exercise modality effect on oxygen uptake off-transient kinetics at maximal oxygen uptake intensity.

NEW FINDINGS What is the central question of this study? Do the mechanical differences between swimming, rowing, running and cycling have a potential effect on the oxygen uptake (V̇O2) off-kinetics after an exercise sustained until exhaustion at 100% of maximal oxygen uptake (V̇O2max) intensity? What is the main finding and its importance? The mechanical differences between exercise modes had a p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical & Biological Engineering & Computing

سال: 2009

ISSN: 0140-0118,1741-0444

DOI: 10.1007/s11517-009-0534-0