Current Transients in CdS/CdTe Solar Cells

Current transient responses to voltage and illumination steps are investigated to elucidate the mechanisms involved in carrier transport in CdS/CdTe cells. For most cells, the response to a dark, forward-bias step after a long dark soak at zero bias is a current growth curve For one such cell, the magnitude of the transient is ≈ 22% of the starting value with half of the growth occurring within...

متن کامل

Current transients in single nanoparticle collision events.

Electrochemical hydrazine oxidation and proton reduction occur at a significantly higher rate at Pt than at Au or C electrodes. Thus, the collision and adhesion of a Pt particle on a less active Au or C electrode leads to a large current amplification by electrocatalysis at single nanoparticles (NPs). At low particle concentrations, the collision of Pt NPs was characterized by current transient...

متن کامل

Current Sources and Ramp Generators

For the analog-to-digital conversion lab, we need a resetable ramp generator. Here, we explore building a ramp generator from a current source. We implement a current source using an operational amplifier (Op Amp or OA) and then using a PNP transistor; the single-ended PNP source is used in the lab.

متن کامل

Measurement of electrogenic-pump current in Aplysia neurones with constant-current and constant-voltage techniques.

1. The responses of the abdominal and pleural giant cells to warming and cooling were studied using constant-current and constant-voltage techniques. 2. The potential change upon warming from about 7 degrees C to 22 degrees C was reversed by application of maintained inward current. The reversal potential was -77 +/- 12 mV. 3. The membrane conductance increased with warming, but was not affecte...

متن کامل

Constant heat characterisation and geometrical optimisation of thermoelectric generators

It is well known that for a thermoelectric generator (TEG) in thermal steady-state with constant temperature difference across it the maximum power point is found at half of the open-circuit voltage (or half of the short-circuit current). However, the effective thermal resistance of the TEG changes depending on the current drawn by the load in accordance with the parasitic Peltier effect. This ...

متن کامل