BACKGROUND Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to record acoustic signals from sources. METHODS An imaging algorithm to analyze th...
متن کاملReal-time acoustic tomography system and the experience of Caspian current sea monitoring
The Acoustic Tomography (AT) systems are used to monitor long-term and continuous flow in rivers, seas and oceans. One of the disadvantages of existing systems in Iran is the inability of real-time/automated measurements. In this study, by adding a raspberry Pi computer to the system and performing the required programming, it was possible to do online monitoring. The data are transferred to th...
متن کاملHybrid Model for Bulk Current Injection Probe
A new hybrid-model for BCI probe is derived . This model is built based on the probe's internal structure without refinements, and by carrying out just one electrical measurement for the reflection coefficient, so that it can be generalized and used in studying the effect of layout parameters in the aim of improving the probe high frequency performance, which helps the developer in design stage...
متن کاملMeasuring the Kuroshio Current with ocean acoustic tomography.
Ocean current profiling using ocean acoustic tomography (OAT) was conducted in the Kuroshio Current southeast of Taiwan from August 20 to September 15, 2009. Sound pulses were transmitted reciprocally between two acoustic stations placed near the underwater sound channel axis and separated by 48 km. Based on the result of ray simulation, the received signals are divided into multiple ray groups...
متن کاملMagneto-photo-acoustic imaging
Magneto-photo-acoustic imaging, a technique based on the synergy of magneto-motive ultrasound, photoacoustic and ultrasound imaging, is introduced. Hybrid nanoconstructs, liposomes encapsulating gold nanorods and iron oxide nanoparticles, were used as a dual-contrast agent for magneto-photo-acoustic imaging. Tissue-mimicking phantom and macrophage cells embedded in ex vivo porcine tissue were u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BioMedical Engineering OnLine
سال: 2016
ISSN: 1475-925X