Transverse Reinforcement in Reinforced Concrete Columns
نویسندگان
چکیده
منابع مشابه
Rehabilitation of Reinforced Concrete Columns
In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...
متن کاملReinforced Concrete Columns in Torsion (RESEARCH NOTE).
ACT does not suggest any regulations for columns under torsion. However, by all means, the number of such columns used in steel and concrete structures is abundant. In this paper, using the results of laboratory tests on 35 square and rectangular columns with intermediate slender ratios, relations for determination of torsional strengths of reinforced concrete under axial compression have been ...
متن کاملSeismic Response of Reinforced Concrete Columns
There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...
متن کاملCombined Transverse Steel-External FRP Confinement Model for Rectangular Reinforced Concrete Columns
Recently, the need to increase the strength of reinforced concrete members has become a subject that civil engineers are interested in tackling. Of the many proposed solutions, fiber-reinforced polymer (FRP) materials have attracted attention due to their superior properties, such as high strength-to-weight ratio, high energy absorption and excellent corrosion resistance. FRP wrapping of concre...
متن کاملEffect of Reinforcement Grade and Ratio on Seismic Performance of Reinforced Concrete Columns
Reinforcement grades higher than 75 ksi (520 MPa) are not allowed in members that form plastic hinges due to a lack of information on material characteristics and on the seismic performance of columns constructed with high-strength steel (HSS) reinforcement. This research investigated the performance of reinforced concrete columns containing Grade 80 (minimum yield strength of 80 ksi [550 MPa])...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: sspjce
سال: 2013
ISSN: 1338-7278,1338-7278
DOI: 10.2478/sspjce-2013-0017