Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization.

We describe a novel code system, TRiP, dedicated to the planning of radiotherapy with energetic ions, in particular 12C. The software is designed to cooperate with three-dimensional active dose shaping devices like the GSI raster scan system. This unique beam delivery system allows us to select any combination from a list of 253 individual beam energies, 7 different beam spot sizes and 15 inten...

متن کامل

Algorithms for Biological Dose Optimization in Ion Beam Radiotherapy

From 1997 until 2008 about 440 cancer patients were successfully treated in the ion therapy project at GSI. The patient treatment planning was performed with the software TRiP [1, 2]. A crucial part of the treatment planning is the particle number optimization with the goal to achieve a target dose distribution as close as possible to the prescribed biological dose distribution. The optimizatio...

متن کامل

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

متن کامل

Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm

Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...

متن کامل

Treatment Planning for the Carbon Ion Radiotherapy

In the three therapy beam times 2007 about 50 patients were planned and treated with our treatment planning software, TRiP98, and its development version, TRiP98BEAM. In the past, the standard method was to optimize the biological target dose distribution for the contributing partial fields singly. Due to the enormous effort for the computation of biological effects, only a simple, but still su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics in Medicine and Biology

سال: 2000

ISSN: 0031-9155,1361-6560

DOI: 10.1088/0031-9155/45/11/313