Twenty-year experience with the St Jude Medical mechanical valve prosthesis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twenty-five year experience with the St. Jude medical mechanical valve prosthesis.

BACKGROUND We evaluated all adult St. Jude mechanical valve recipients at our institution since the initial implant in January 1979 and now present our 25-year experience. METHODS Nine hundred forty-five valve recipients were followed prospectively at 12-month intervals from January 1979 to December 2007. RESULTS Operative mortality was 3% in the aortic valve recipients and 5% in the mitral...

متن کامل

The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

BACKGROUND From October 1977 to October 2002, 4,480 patients (age range, 17 to 94 years; average, 64 +/- 13 years) underwent single valve replacement with the St. Jude Medical heart valve. Of 2,982 aortic (AVR) and 1,498 mitral valve replacements (MVR), concomitant coronary artery bypass grafting was performed on 42% and 33%, respectively. METHODS Cardiac Surgical Associates has maintained an...

متن کامل

Twenty-year experience with the St. Jude medical Biocor bioprosthesis in the aortic position.

BACKGROUND The purpose of this study was to evaluate the long-term performance of the St. Jude Medical Biocor stented porcine prosthesis in the aortic position. METHODS From January 1985 to December 1996, 455 patients admitted for aortic valve replacement were consecutively enrolled in this study. The mean age was 72.5 +/- 9 years, 18 patients (3.5%) had had previous cardiac surgery, and coro...

متن کامل

Long-term outcomes after St. Jude Medical mechanical valve implantation.

patient-year), major bleeding events (1.0%/patient-year), and aortic valve reoperation (0.26%/patient-year). They also reported that valve-related death was the most common cause of death (26.8%) and that the rates of freedom from valve-related death were 96.2%, 92.7%, 88.8%, and 86.6% at 5, 10, 15, and 20 years, respectively. These results compare favorably with the findings of previous report...

متن کامل

Transcatheter aortic valve replacement with the St. Jude Medical Portico valve: first-in-human experience.

OBJECTIVES The purpose of this study was to demonstrate the feasibility and procedural outcomes with a new self-expanding and repositionable transcatheter heart valve. BACKGROUND Transcatheter aortic valve replacement is a viable option for selected patients with severe symptomatic aortic stenosis. However, suboptimal prosthesis positioning may contribute to paravalvular regurgitation, atriov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Thoracic and Cardiovascular Surgery

سال: 2003

ISSN: 0022-5223

DOI: 10.1016/j.jtcvs.2003.07.005