Two-layer self-powered active seismic isolation floor
نویسندگان
چکیده
منابع مشابه
Two Layer 3D Floor Planning
A 3D floor plan is a non-overlapping arrangement of blocks within a large box. Floor planning is a central notion in chip-design, and with recent advances in 3D integrated circuits, understanding 3D floor plans has become important. In this paper, we study so called mosaic 3D floor plans where the interior blocks partition the host box under a topological equivalence. We give representations wh...
متن کاملMulti-axial Active Isolation for Seismic Protection of Buildings
Structural control technology has been widely accepted as an effective means for the protection of structures against seismic hazards. Passive base isolation is one of the common structural control techniques used to enhance the performance of structures subjected to severe earthquake excitations. Isolation bearings employed at the base of a structure naturally increase its flexibility, but con...
متن کاملSelf-Powered Active Sensor with Concentric Topography of Piezoelectric Fibers
In this study, we demonstrated a flexible and self-powered sensor based on piezoelectric fibers in the diameter range of nano- and micro-scales. Our work is distinctively different from previous electrospinning research; we fabricated this apparatus precisely via near-field electrospinning which has a spectacular performance to harvest mechanical deformation in arbitrary direction and a novel c...
متن کاملStudy on the Self-powered Active Vibration Control
A method of active vibration control using regenerated vibration energy, i.e., the self-powered active vibration control is proposed. In this system, vibration energy is regenerated with an electric generator ,which is called energy regenerative damper, and is stored in a condenser. An actuator attains active vibration control using the energy stored in the condenser. A variable resistance is u...
متن کاملResearch on Base Isolation for Seismic Retrofitting of Adjacent Structures Connected with a Large Floor
Received: December 19, 2016 Revised: February 06, 2017 Accepted: March 20, 2017 Abstract: Introduction: Seismic isolation has been proven to be an efficient approach to seismic retrofitting of structures based on the concept of reducing the seismic forces by lengthening the structural fundamental vibration period. However, superstructures may collide with each other under seismic excitation as ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the JSME (in Japanese)
سال: 2014
ISSN: 2187-9761
DOI: 10.1299/transjsme.2014dr0121