Ultrahigh Resolution OCT Using Supercontinuum
نویسندگان
چکیده
منابع مشابه
Ultrahigh Resolution OCT System for Real - time In Vivo Imaging
s and Conference Proceedings X. Li, T. H. Ko, and J. G. Fujimoto, “Intraluminal fiber optic Doppler imaging catheter for structural andfunctional optical coherence tomography,” Photonics West, SPIE, San Jose, CA, January 19-25, 2002,paper 4619-22. T. H. Ko, I. Hartl, W. Drexler, R. K. Ghanta, and J. G. Fujimoto, “Ultrahigh resolution optical coherencetomography for quantitative topo...
متن کاملEnhanced visualization of choroidal vessels using ultrahigh resolution ophthalmic OCT at 1050 nm.
In this article the ability of ultrahigh resolution ophthalmic optical coherence tomography (OCT) to image small choroidal blood vessels below the highly reflective and absorbing retinal pigment epithelium is demonstrated for the first time. A new light source (lambdac= 1050 nm, Deltalambda = 165 nm, Pout= 10 mW), based on a photonic crystal fiber pumped by a compact, self-starting Ti:Al2O3 las...
متن کاملUltrahigh resolution retinal imaging by visible light OCT with longitudinal achromatization
Chromatic aberrations are an important design consideration in high resolution, high bandwidth, refractive imaging systems that use visible light. Here, we present a fiberbased spectral/Fourier domain, visible light OCT ophthalmoscope corrected for the average longitudinal chromatic aberration (LCA) of the human eye. Analysis of complex speckles from in vivo retinal images showed that achromati...
متن کاملHigh-speed ultrahigh-resolution OCT of Bruch's membrane in membranoproliferative glomerulonephritis type 2.
Membranoproliferative glomerulonephritis (MPGN) type 2 is characterized by electron-dense deposits in the glomerular basement membrane and drusen-like deposits in Bruch's membrane. Over time, atrophic changes in the retina and retinal pigment epithelium occur, which can progress to choroidal neovascularization (CNV). This report describes a patient with MPGN type 2 who developed progressive los...
متن کاملUltrahigh resolution mass spectrometry
The integration of soft ionization technologies and ultrahigh resolution FTICR mass spectrometry (Fourier transform ion-cyclotron MS) has enabled the examination of molecules, directly from mixtures, with ultrahigh mass resolution and sub-ppm mass accuracy. This ability to observe structure and reactivity aspects of intact (macro)molecules has, in particular, contributed to the molecular-level ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nippon Laser Igakkaishi
سال: 2015
ISSN: 0288-6200,1881-1639