Ultrashort electron bunch length measurement with diffraction radiation deflector

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Sub-picosecond Bunch Length with the Interferometry from Double Diffraction Radiation Target*

Reliable and precise methods for non-invasive diagnostics of sub-picosecond electron bunches are required for new accelerator facilities (FEL, LWFA, et al.). Measurements of spectral characteristics of coherent radiation generated by such bunches using interferometer allow to determine a bunch length [1]. Here we present a compare experimental study between the measurement from the double diffr...

متن کامل

Novel Single Shot Bunch Length Diagnostic Using Coherent Diffraction Radiation

Current beam bunch length monitors that measure the spectral content of beam-associated coherent radiation to determine the longitudinal bunch form factor usually require wide bandwidth detection, Fourier transformation of spectral or interferometric data, phase retrieval algorithms and multiple beam pulses to obtain the bunch length. In this paper we discuss progress in the development of a no...

متن کامل

Optical circular deflector with attosecond resolution for ultrashort electron beam

A novel method using high-power laser as a circular deflector is proposed for the measurement of femtosecond (fs) and sub-fs electron beam. In the scheme, the electron beam interacts with a laser pulse operating in a radially polarized doughnut mode (TEM01 ) in a helical undulator, generating angular kicks along the beam in two directions at the same time. The phase difference between the two a...

متن کامل

Bunch Length Measurements at Ttf Using Coherent Diffraction Radiation

The coherent diffraction radiation technique has been for the first time intentionally employed in the bunch length measurements at the TTF linac. Diffraction radiation (DR) is emitted as a beam passes through an aperture in a highly reflecting screen and, therefore, in contrast to transition radiation (TR), is a really non-intercepting tool a very attractive feature to diagnose high-power beam...

متن کامل

Proposed Coherent Diffraction Radiation Measurements of Bunch Length at Asta

The feasibility of using the autocorrelation of coherent diffraction radiation (CDR) as a non-intercepting diagnostics technique for bunch length and indirectly rf phase measurements is evaluated and proposed for the Advanced Superconducting Test Accelerator (ASTA) facility under construction at Fermilab. Previous experiments on an rf thermionic cathode gun beam at 50 MeV provide a proof-of-pri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Special Topics - Accelerators and Beams

سال: 2007

ISSN: 1098-4402

DOI: 10.1103/physrevstab.10.012801