Ultrasonic 3-D Vector Flow Method for Quantitative In Vivo Peak Velocity and Flow Rate Estimation
نویسندگان
چکیده
منابع مشابه
Peak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملA posteriori accuracy estimation of ultrasonic vector-flow mapping (VFM)
ABSTRACT A novel method, called a posteriori "VFM accuracy estimation" (VAE), for resolving an intrinsic VFM problem is proposed. The problem is that VFM uncertainty can easily vary according to blood flows through an echocardiographic imaged plane (i.e., "through-plane" flows), and it is unknown. Knowing the VFM uncertainty for each patient will make it possible to refine the quality of VFM-ba...
متن کاملRelationship of peak flow rate and peak velocity time during after voluntary coughing
The differences in phonation between men and women are thought to occur from anatomical differences in the larynx. However, it is not known if there are any differences in cough dynamics between the sexes. We investigated this by asking 100 healthy, non-smoking adults (50 male) to perform a voluntary cough into a tussometer. Each volunteer coughed at four different lung volumes, ranging from to...
متن کاملEstimation of Runoff Peak Flow by El-Hames Empirical Method for Ungauged Catchments: A Case Study Iranshahr
In this paper, the El-Hames empirical method was used to determine the peak runoff flow in Iranshahr catchment. The El-Hames method is based on morphological parameters and SCS Curve Number of the studied area. The implementing was processed by collecting the required data including soil type and vegetation cover, land use maps, digital elevation model and satellite images from the associated i...
متن کاملQuantitative blood flow velocity imaGinG
Laser speckle flowmetry suffers from a debated quantitative relationship with blood flow, velocity or tissue perfusion and a lack of calibration of the inverse relationship 1/τc = αV between decorrelation time (τc) and flow velocity (V). Using a modified microcirculation imager, we experimentally investigate on the influence of the optical properties of scatterers on α in vitro and in vivo. We ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
سال: 2017
ISSN: 0885-3010,1525-8955
DOI: 10.1109/tuffc.2016.2639318