Ultrasonic absorption and attenuation in mammalian tissues.

-The ultrasonic absorption was determined, by the transient thermoelectric method, for brain, heart, kidney, liver, tendon, and testis from cat, mouse, pig and beef. Comparison of these absorption {a) values with published values of attenuation (A) shows: (1) that the a and A coefficients have nearly the same frequency dependencies in the range 0.5-7 MHz, (2) that the magnitudes of a and A diff...

متن کامل

Frequency dependence of ultrasonic absorption in mammalian testis.

The earlier report that the frequency dependence of ultrasonic absorption of mammalian testis memicked a single relaxation process is explained as an effect of ultrasonic beam width upon the transient thermoelectric technique. More detailed measurements show that the frequency dependence of the ultrasonic absorption in testis is much the same as the attenuation in other soft tissues, viz., a pr...

متن کامل

Compilation of empirical ultrasonic properties of mammalian tissues. II.

The compilation of the literature on ultrasonic propagation properties of mammalian tissues [J. Acoust. Soc. Am. 64, 423 (1978)] is continued with the addition of 45 papers yielding over 700 lines of parametric data.

متن کامل

Ultrasonic Attenuation in Solid Helium

A great deal of information about the motion of dislocations in solid helium has been obtained from ultrasonic and interna1 friction measurements. A brief review is given and representative data for 3 ~ e are presented, showing dislocation resonance and damping as well as pinning effects.

متن کامل

Ultrasonic attenuation and backscattering by mammalian organs as a function of time after excision.

Ultrasonic attenuation and backscattering were measured for bovine brain, spleen and liver and for porcine iiver as a function of time after excision for times up to 12Ohr. Tine attenuation coeificient exhibits insigniticant chaoges while the mean backscattering amplitude decreases substantiahy during the period such specimens are likely to be used. The changes in the two parameters are believe...