Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers.

A photoacoustic tomography system (PAT) using virtual point ultrasonic transducers was developed and applied to image a monkey brain. The custom-built transducers provide a 10-fold greater field-of-view (FOV) than finite-aperture unfocused transducers as well as an improved signal-to-noise ratio (SNR) and reduced artifacts rather than negative-lens transducers. Their tangential resolution, radi...

متن کامل

Ultrasonic Lamb wave tomography

Nondestructive evaluation (NDE) of aerospace structures using traditional methods is a complex, time-consuming process critical to maintaining mission readiness and flight safety. Limited access to corrosion-prone structure and the restricted applicability of available NDE techniques for the detection of hidden corrosion or other damage often compound the challenge. In this paper we discuss our...

متن کامل

Airborne Ultrasonic Transducers for Ultrasonic Transmission Tomography in Gaseous Media

Ultrasonic transmission tomography is one of the measurement methods used for imaging of internal structure of various media. The method can be used in gaseous media, e.g. to identify the shape, size and location of objects, to determine the spatial distribution of temperature in a studied area (if here is a heterogeneous field of that quantity) and to determine concentration of components of s...

متن کامل

Continuous wave ultrasonic Doppler tomography.

In continuous wave ultrasonic Doppler tomography (DT), the ultrasonic beam moves relative to the scanned object to acquire Doppler-shifted frequency spectra which correspond to cross-range projections of the scattering and reflecting structures within the object. The relative motion can be circular or linear. These data are then backprojected to reconstruct the two-dimensional image of the obje...

متن کامل

Velocity Inversion with an Iterative Normal Incidence Point (NIP) Wave Tomography with Model-Based Common Diffraction Surface (CDS) Stack

Normal Incidence Point (NIP) wave tomography inversion has been recently developed to generate a velocity model using Common Reflection Surface (CRS) attributes, which is called the kinematic wavefield attribute. In this paper, we propose to use the model based Common Diffraction Surface (CDS) stack method attributes instead of data driven Common Reflection Surface attributes as an input data p...