Ultrasound field measurement using a binary lens
نویسندگان
چکیده
منابع مشابه
Direct measurement of circulation using ultrasound
Ultrasound time-of-flight methods employing counter-propagating ultrasonic pulses are utilized for the direct measurement of circulation in vortical flows. Two schemes are described here which involve either a single straight path or a closed path. Both techniques are shown to result in time differences, between the counter-propagating pulses around the path, linearly proportional to the circul...
متن کاملBinary subwavelength diffractive-lens design.
We present a procedure for the design of binary diffractive lenses with pulse-width-modulated subwavelength features. The procedure is based on the combination of two approximate theories, effective medium theory and scalar diffraction theory, and accounts for limitations on feature size and etch depth imposed by fabrication. A design example is presented.
متن کاملMeasurement of vertebral rotation using a three-dimensional ultrasound image
Materials and methods Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. The rotation angles of the cadaveric vertebra were recorded during the experiment. Nine sets of ultrasound data, from 0 to 40° with 5° increments, were recorded from each vertebra (27 sets in total). An in-house program was used to reconstruct the 3D vertebra images. The rotation of ...
متن کاملMeasurement of infant tongue thickness using ultrasound: a technical note.
Novel uses of ultrasound include obtaining images of intra-oral structures to further research in speech production and feeding. In this technical note we describe a noninvasive, cost-effective, and reliable method for measuring infant tongue muscle thickness. The current pilot study demonstrates high reliability of a trained ultrasonographer to obtain adequate images of the infant tongue and t...
متن کاملMeasurement of the crystalline lens radius with artemis very high frequency ultrasound biomicroscopy for implantable collamer lens sizing.
To the Editor: In their recent article, Reinstein et al.1 described the use of the Artemis 2 very high frequency digital ultrasound (ArcScan, Inc., Morrison, CO) to calculate the fit of the Visian Implantable Collamer Lens (ICL). Another parameter previously proposed as influencing ICL vaulting is the crystalline lens anterior radius of curvature (ALR).2 The ALR has not yet been used in any pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
سال: 2015
ISSN: 0885-3010
DOI: 10.1109/tuffc.2014.006800