Unique interpretation of Talbot Bands and Fourier domain white light interferometry

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unique interpretation of Talbot Bands and Fourier domain white light interferometry.

A theoretical model is developed to interpret the output of the diffraction grating spectrometer used to analyze the channelled spectrum produced by a low coherence interferometer set-up. This model leads to an unique interpretation which covers both cases (i) of Talbot bands and (ii) of a Michelson interferometer used in most spectral interferometry set-ups for sensing as well as for Fourier d...

متن کامل

Fourier Transforms By White-Light Interferometry: Michelson Stellar Interferometer Fringes

The white-light compensated rotational shear interferometer (coherence interferometer) was developed in an effort to study the spatial frequency content of passively illuminated white-light scenes in real-time and to image sources of astronomical interest at high spatial frequencies through atmospheric turbulence. This work was inspired by Professor Goodman’s studies of the image formation prop...

متن کامل

Fourier-domain low-coherence interferometry for light-scattering spectroscopy.

We present a novel method for obtaining depth-resolved spectra for determining scatterer size through elastic-scattering properties. Depth resolution is achieved with a white-light source in a Michelson interferometer with the mixed signal and reference fields dispersed by a spectrograph. The spectrum is Fourier transformed to yield the axial spatial cross correlation between the signal and ref...

متن کامل

Basics of White-Light Interferometry

Interferometer Setup The Twyman–Green interferometer (Figure 1) is a special configuration of the well-known Michelson interferometer with optics that superimpose the images of the object and the reference planes. Polytec engineers use this interferometer and place a CCD image sensor like those used for digital photography at the point where the two images are superimposed. A broadband “white-l...

متن کامل

Moiré interferometry with white light.

While high-sensitivity moiré interferometry requires monochromatic light, an auxiliary compensator grating removes the requirement. Experimental verification utilized white light for moiré interference of sensitivity 0.833 microm/fringe. Configurations readily amenable to compensation include moiré fringe multiplication by even factors and the minimum-deviation arrangement. Chromatic compensati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2007

ISSN: 1094-4087

DOI: 10.1364/oe.15.009867