Unlimited-Volume Electrokinetic Stacking Injection in Sweeping Capillary Electrophoresis Using a Cationic Surfactant

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unlimited-volume electrokinetic stacking injection in sweeping capillary electrophoresis using a cationic surfactant.

Sweeping is an effective and convenient way for online sample preconcentration in micellar electrokinetic chromatography. The usual procedure includes a hydrodynamic injection step carried out by applying pressure to the sample vial followed by the subsequent sweeping and separation processes. The injected sample volume is limited by the dimensions of the capillary because a part of the capilla...

متن کامل

Flow manipulation for sweeping with a cationic surfactant in microchip capillary electrophoresis.

Flow manipulation in sweeping microchip capillary electrophoresis (CE) is complicated by the free liquid communication between channels at the intersection, especially when the electroosmotic flows are mismatched in the main channel. Sweeping in traditional CE with cationic micelles is an effective way to concentrate anionic analytes. However, it is a challenge to transfer this method onto micr...

متن کامل

Pneumatic Microvalve for Electrokinetic Sample Preconcentration and Capillary Electrophoresis Injection

Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefl...

متن کامل

Large-volume sample sweeping with a high theoretical plate number using a coupled-capillary in capillary electrophoresis.

A large-volume sample injection (> 5 microL) with an extremely high theoretical plate number (N > 10(7)) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 microm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED ( approximately 2 mW) was used as the fluorescence excitation source. As a result, the theoretica...

متن کامل

An alternative interface for a flow injection-capillary electrophoresis system with electrokinetic injection.

An alternative interface for flow injection-capillary electrophoresis based on electrokinetic injection is described. The interface basically consists of tubular platinum and a commercially available standard tee connector. The tubular platinum works as not only an electrode, but also a waste outlet of a split sample solution. The availability of the proposed interface is evaluated by the separ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Chemistry

سال: 2006

ISSN: 0003-2700,1520-6882

DOI: 10.1021/ac060298x