Update on infectious risks associated with dental unit waterlines

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are dentists enough aware of infectious risk associated with dental unit waterlines ?

Environmental conditions in DU encourage biofilm development. This biofilm may represent a risk for patients and dental staff exposed to water and aerosols generated during dental cares, particularly for immunocompromised persons. A survey was conducted on the 175 dental surgeons of the department of Vienne (France) to investigate the motivations of dental practitioners to renew their DU, their...

متن کامل

Microbial contamination in dental unit waterlines.

The quality of water in a dental unit is of considerable importance because patients and dental staff are regularly exposed to water and aerosol generated from the dental unit. The aim of this study was to evaluate the occurrence of microbial contamination in dental unit waterlines. Water samples were collected aseptically from the waterlines (reservoir, triple-syringe, high-speed) of 15 dental...

متن کامل

Microbial contamination of dental unit waterlines.

The specific structure of dental units favours the presence of biofilm and microbial contamination of the dental unit waterlines (DUWL) water. The ability of bacteria to colonize surfaces and to form biofilm in water supply tubes, including DUWL, is a common phenomenon, which has been well documented, just as with difficulties in biofilm removal and prevention of its regrowth. Microorganisms fr...

متن کامل

Bacterial contamination of dental unit waterlines

Safety of patients and dental personnel requires the appropriate microbiological water quality in dental units. During treatment, patients and dental workers are exposed both to direct contact with bacteria-contaminated water in the form of splatter and with contaminated water aerosol emitted during work by unit handpieces, including rotating and ultrasonic instruments. The aim of the study was...

متن کامل

Microbial diversity in dental unit waterlines.

Dental health care providers and patients are exposed during ongoing work to contamination by the water used in the dental units, due to accidental swallowing or aspiration of the sprays generated by the high-speed handpiece and the threeway syringe. This study evaluated the quality of water in dental units in the public dental care system of Maceio, Alagoas, Brazil, by conducting analyses of c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: FEMS Immunology & Medical Microbiology

سال: 2012

ISSN: 0928-8244,1574-695X

DOI: 10.1111/j.1574-695x.2012.00971.x