Updating the ELISA standard curve fitting process to reduce uncertainty in estimated microcystin concentrations
نویسندگان
چکیده
منابع مشابه
The ELISA Standard Save: calculation of sample concentrations in assays with a failed standard curve.
The enzyme-linked immunosorbent assay (ELISA) is often used to measure protein levels in plasma and other solutions. In order for the assay to be quantitative, a standard curve must be prepared for each assay. Technical blunders in preparing the standard curve can render otherwise representative sample values useless. In order to recover these data, a protocol has been developed whereby a new s...
متن کاملEfficiently Updating Feasible Regions for Fitting Discrete Polynomial Curve
We deal with the problem of fitting a discrete polynomial curve to 2D data in the presence of outliers. Finding a maximal inlier set from given data that describes a discrete polynomial curve is equivalent with finding the feasible region corresponding to the set in the parameter space. When iteratively adding a data point to the current inlier set, how to update its feasible region is a crucia...
متن کاملDetection limit estimated from slope of calibration curve: an application to competitive ELISA.
This paper theoretically derives a general rule that while the slope of the semi-logarithmic plot (Y vs. log X) of a calibration curve varies depending on analyte concentration, X, the slope takes a specific value at the detection limit (L(D)). This rule holds good irrespective of the shape of the calibration curve (linear or non-linear) and in this paper, is applied to competitive ELISA (enzym...
متن کاملSignal detection Using Rational Function Curve Fitting
In this manuscript, we proposed a new scheme in communication signal detection which is respect to the curve shape of received signal and based on the extraction of curve fitting (CF) features. This feature extraction technique is proposed for signal data classification in receiver. The proposed scheme is based on curve fitting and approximation of rational fraction coefficients. For each symbo...
متن کاملA Bayesian Curve Fitting Approach to
A Bayesian method of estimating the power spectra of stationary random processes is proposed. Initially we estimate the true spectra via the log pe-riodogram but due to the inadequacies of the periodogram when the true spectrum has a high dynamic range and/or is rapidly varying for such problems we use the multitaper spectrum estimates which have known error distributions. Piecewise polynomials...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MethodsX
سال: 2018
ISSN: 2215-0161
DOI: 10.1016/j.mex.2018.03.011