Upper limit of vulnerability and heterogeneity

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular apex ablation decreases the upper limit of vulnerability.

BACKGROUND After shocks with an approximately 50% probability of success for the upper limit of vulnerability (ULV(50)) of strength, the first few activations appear focally on the epicardium at almost the same site at the left ventricular (LV) apex in both successful and failed induction of ventricular fibrillation (VF). We tested the hypothesis that subendocardial ablation at this early site ...

متن کامل

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

Relation between upper limit of vulnerability and defibrillation threshold in humans.

BACKGROUND In the canine model, an upper limit of shock strength exists that can induce ventricular fibrillation during the vulnerable period of the cardiac cycle. This shock strength (the upper limit of vulnerability) closely correlates with the defibrillation threshold and supports the "upper limit of vulnerability" hypothesis of defibrillation. It is not known whether an upper limit of vulne...

متن کامل

Effect of acute global ischemia on the upper limit of vulnerability: a simulation study.

The goal of this modeling research is to provide mechanistic insight into the effect of altered membrane kinetics associated with 5-12 min of acute global ischemia on the upper limit of cardiac vulnerability (ULV) to electric shocks. We simulate electrical activity in a finite-element bidomain model of a 4-mm-thick slice through the canine ventricles that incorporates realistic geometry and fib...

متن کامل

Determination of the upper limit of vulnerability using implantable cardioverter-defibrillator electrograms.

BACKGROUND The upper limit of vulnerability (ULV) correlates with the defibrillation threshold and can be determined with 1 episode of ventricular fibrillation (VF). To automate the ULV in an implantable cardioverter-defibrillator (ICD), the most vulnerable intervals must be identified from an ICD electrogram rather than the latest-peaking surface T wave (Tpeak). We hypothesized that the recove...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Heart Rhythm

سال: 2009

ISSN: 1547-5271

DOI: 10.1016/j.hrthm.2008.11.032