Use of a multileaf collimator to increase the field width achievable with a dynamic wedge

A method is proposed for generating dynamic wedges spanning the entire field width, defined as the collimator opening in the wedged direction, without changes to existing hardware. The technique approximates the fluence pattern of a dynamic wedge by sequentially closing the leaves of a 120-leaf multileaf collimator (MLC). Closure times for the individual leaves were derived by extending the seg...

متن کامل

Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge

The American Association of Physicists in Medicine Task Group 36 (AAPM TG-36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary multileaf collimators have been shown to significantly affect PD distribution...

متن کامل

Generation of wedge‐shaped dose distributions through dynamic multileaf collimator dose delivery

A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to the intensity-modulated radiation therapy (IMRT) leaf sequence generation algori...

متن کامل

A new algorithm for optimal multileaf collimator field segmentation

We present a new efficient leaf sequencing algorithm for the generation of intensity maps by a nonnegative combination of segments. Intensity maps describe the intensity modulation of beams in radiotherapy. We only study the static case (stop and shoot) an optimize the total number of monitor units and the number of segments. We will present a short exact proof for a formula giving the smallest...

متن کامل

[Testing of dynamic multileaf collimator by dynamic log file].

Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy. In the dynamic multileaf collimator (MLC) method of IMRT delivery, because of the relatively small gaps between opposed leaves and because most regions are shielded by leaves most of the time, the delivered dose is very sensitive to MLC leaf positional accuracy. A variati...