Use of evaporative cooling units in solar air conditioning installations
نویسندگان
چکیده
The paper describes the calculation of evaporative-radiant cooling recycled water in summer air-conditioning systems. A differential equation for heat balance flowing down an inclined plane is derived. As one possible way increasing efficiency air conditioning systems based on by adiabatic evaporation flow use night-time evaporative water, followed daytime insulated storage tanks. temperature chilled this 3-4 ℃ lower than during day, and final close to saturation outside air. equations mass transfer coefficients, radiation coefficient bottom water-cooling unit are given. Based Mathcad program result calculation, dependence initial obtained. a specific capacity radiant production free determined.
منابع مشابه
Architectural repercussions of the air conditioning installations
This work aims to present an analysis of architectural repercussions involved in choosing a certain climatic system for an office block. The intention is to unite techniques and the building itself. Independently of the bioclimatic design criteria for office work, these buildings require active technical systems for their air conditioning. We should only consider the air conditioning option tha...
متن کاملGreen Practices Of Air Conditioning For Major Capital Cities Of India Using Advanced Evaporative Cooling
In the present era of energy crisis, effective and energy efficient air conditioning is a need of time. Advanced evaporative cooling is able to replace conventional air conditioning. This paper identifies the major cities of India and investigates scope and potential of evaporative cooling over entire period of year using feasibility index method. Initially paper describes basic and advanced me...
متن کاملMethods for Analyzing the Energy Efficiencyand Cost Effectiveness of Evaporative Cooling Air Conditioning
Air conditioning systems of houses consume large quantity of electricity. To reducing energy consumption for air conditioning purposes it is becoming attractive the use of evaporative cooling air conditioning which is less energy consuming compared to air chillers. But, it is obvious that higher energy efficiency of evaporative cooling is not enough to judge whether evaporative cooling economic...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2023
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202338304049