Use of low ionic strength saline for crossmatching and antibody screening.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of low ionic strength saline for crossmatching and antibody screening.

A totally revised crossmatching and antibody screening procedure has been designed using low ionic strength saline as the suspending medium for red cells in the saline and enzyme phases as well as the antiglobulin test. The replacement of Pasteur pipettes with precision samplers for all serum and red cell dispensing has resulted in improvement in the reproducibility and standardisation of techn...

متن کامل

Low Ionic Strength Buffer for One Litre

SYNOPSIS Erythrocytes may be coated with blood group antibodies with or without reacting complement or sometimes apparently with complement alone. This may occur in vivo in such conditions as autoimmune acquired haemolytic anaemia, haemolytic disease of the newborn, or after transfusions of incompatible blood. It may occur in vitro also by the deliberate sensitization of erythrocytes during lab...

متن کامل

Quinine Fluorescence Quenching at Low Ionic Strength

The effect of ionic activity on the quenching of the quinine dication fluorescence by chloride and bromide ions is examined in solutions of sufficiently low ionic strength to enable ionic activities to be taken into account by means of the Debye-Hückel equation. An equation for the dependence of the Stern-Volmer constant on the ionic strength is derived in a novel way and an iterative, linear l...

متن کامل

the use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach

abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...

15 صفحه اول

Effect of ionic strength on the formal potential of the glass electrode in various saline media.

We examined the variation with ionic strength (I, adjusted with KCl, KNO(3), KBr, NaCl or NaClO(4)) of the formal potential (E(const)) for glass electrodes exhibiting a Nernstian response (i.e. E(cell)=E(const)-slog[H(+)]). For this purpose, we investigated the different factors included in the formal potential, so we obtained reported values for the liquid junction potential as a function of i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Pathology

سال: 1979

ISSN: 0021-9746

DOI: 10.1136/jcp.32.10.1019