Use of Maximum End-Tidal CO2 Values to Improve End-Tidal CO2 Monitoring Accuracy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of maximum end-tidal CO(2) values to improve end-tidal CO(2) monitoring accuracy.

BACKGROUND The arterial partial pressure of CO(2) (P(aCO(2))) can be grossly estimated by the end-tidal partial pressure of CO(2) (P(ETCO(2))). This principle is used in SmartCare (Dräger, Lübeck, Germany), which is an automated closed-loop system that uses P(ETCO(2)) to estimate alveolar ventilation during mechanical ventilation. OBJECTIVE To assess whether the maximum P(ETCO(2)) value (inst...

متن کامل

Utility of Prehospital Quantitative End Tidal CO2?

INTRODUCTION End tidal CO2 (ETCO2) has been established as a standard for confirmation of an airway, but its role is expanding. In certain settings ETCO2 closely approximates the partial pressure of arterial CO2 (PaCO2) and has been described as a tool to optimize a patient's ventilatory status. ETCO2 monitors are increasingly being used by EMS personnel to guide ventilation in the prehospital ...

متن کامل

Comparison of ventilator-integrated end-tidal CO2 and transcutaneous CO2 monitoring in home-ventilated neuromuscular patients.

BACKGROUND Non-invasive transcutaneous capnometry (TcCO2) is used to assess the home ventilation's efficiency. Recently, end-tidal CO2 (ETCO2) sensors have been integrated in life-support home ventilators. The purpose of this study was to compare the ventilator-integrated ETCO2 with TcCO2, in home-ventilated neuromuscular disease patients. METHODS ETCO2 and TcCO2 were simultaneously measured ...

متن کامل

A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2.

OBJECTIVE The objective of this study was to evaluate a novel method of distal end-tidal CO2 capnography by comparison with PaCO2 and with the more standard method that measures mainstream proximal end-tidal CO2 in intubated infants. METHODS Included in the study were all infants who were ventilated with conventional mechanical ventilation and intubated with a double-lumen endotracheal tube i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Respiratory Care

سال: 2011

ISSN: 0020-1324,1943-3654

DOI: 10.4187/respcare.00837