Use of Scheimpflug corneal anterior-posterior imaging in ray-tracing intraocular lens power calculation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Lens Power Calculation after Corneal Refractive Surgery

PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...

متن کامل

[Intraocular lens power calculation after corneal photorefractive surgery. Literature review].

OBJECTIVE Revision of methods for estimating corneal power (Kpost) and effective lens position (ELP) for cataract surgery after corneal refractive surgery. METHODS Review of medical literature. RESULTS To calculate the intraocular lens that achieves emetropia after corneal refractive surgery it is necessary to correct the Kpost and to estimate the effective lens position again correcting it...

متن کامل

Estimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography

PURPOSE To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subseq...

متن کامل

comparison of corneal power and intraocular lens power calculation methods after lasik for myopia

purpose : to evaluate the accuracy of the two methods the clinical history method (chm), and the contact lens method (clm), in refractive corneal power determination and comparing the accuracy of srk ii, srk t and holladay ii (h ii) formulas for intraocular lens (iol) power calculation in patients who had laser in situ keratomileusis (lasik) surgery for myopia with or without astigmatism method...

متن کامل

Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method.

Purpose To evaluate the accuracy of IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio. Methods Nine hundred twenty-eight eyes from 928 reference subjects and 158 eyes from 158 cataract patients who underwent phacoemulsification surgery were enrolled. Adjusted corneal power of cataract patients was calculated using the fictitio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Ophthalmologica

سال: 2013

ISSN: 1755-375X

DOI: 10.1111/aos.12139