Using a Scanner to Measure Absorbed Doses with Radiochromic Film Dosimeters
نویسندگان
چکیده
The article provides a sequence of steps for using RISØ calorimeters calibration and subsequent use B3 radiochromic film dosimeters (GEX corporation) scanner measuring absorbed doses. Calibration was carried out with the help electron beam accelerator in range doses 3 – 40 kGy (measurement calorimeters). In course work, following out: dosimetry films calorimeters; plotting curve dosimetric films; calculation approximation functions; development technique flatbed to measure doses; estimation measurement uncertainties Accelerator operation parameters: scanning frequency accelerated 5 Hz, pulse 120 energy MeV, current 60 μA. error dose is 5.8 %.
منابع مشابه
Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry
The purpose of this study was to quantify the performance and assess the utility of two different types of scanners for radiochromic EBT film dosimetry: a commercial flatbed document scanner and a widely used radiographic film scanner. We evaluated the Epson Perfection V700 Photo flatbed scanner and the Vidar VXR Dosimetry Pro Advantage scanner as measurement devices for radiochromic EBT film. ...
متن کاملComparison of Epson scanner quality for radiochromic film evaluation
Epson Desktop scanners have been quoted as devices which match the characteristics required for the evaluation of radiation dose exposure by radiochromic films. Specifically, models such as the 10000XL have been used successfully for image analysis and are recommended by ISP for dosimetry purposes. This note investigates and compares the scanner characteristics of three Epson desktop scanner mo...
متن کاملReference dosimetry using radiochromic film
The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparin...
متن کاملApplication of a color scanner for 60Co high dose rate brachytherapy dosimetry with EBT radiochromic film
UNLABELLED BACKGROUND.: The aim of this study is to evaluate the performance of a color scanner as a radiochromic film reader in two dimensional dosimetry around a high dose rate brachytherapy source. MATERIALS AND METHODS A Microtek ScanMaker 1000XL film scanner was utilized for the measurement of dose distribution around a high dose rate GZP6 (60)Co brachytherapy source with GafChromic® EBT...
متن کاملRadiochromic Film Dosimetry
Published by the American Association of Physicists in Medicine DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: East European journal of physics
سال: 2022
ISSN: ['2312-4539', '2312-4334']
DOI: https://doi.org/10.26565/2312-4334-2022-1-12