Vacuum pumping system of 13meter diameter space chamber.
نویسندگان
چکیده
منابع مشابه
Modelling the Differential Pumping of the TASCA Gas-Vacuum System
The scientific program at the TASCA gas-filled separator [1] requires the highest possible UNILAC beam intensities. Presently, they are of the order of one particle microampere and a significant increase is in preparation. To make use of these intensities a windowless differential pumping system (DPS) was installed and a computer program was developed to simulate vacuum conditions at various se...
متن کاملThe vacuum control system design in ultracentrifuge chamber
The ultracentrifuge rotor usually works at 30,000 r/min or more, so centrifuge chamber must maintain a high vacuum to reduce friction of rotor and air. The paper described the vacuum control system design based on MSP430 microcontroller. The system included the MCU, sensors, measurement and conditioning circuitry, vacuum control circuit, power circuit components and so on. Tests proved that the...
متن کاملRarefied Background Flow in a Vacuum Chamber
Spacecraft propulsion systems, such as Hall thrusters, are designed and tested in large vacuum chambers. The pumping capacity of modern facilities makes it possible to maintain pressures as low as 3 10 4 10 Pa. In this study, several free molecular models are developed to analyze the background flow inside a vacuum chamber. These models lead to various sets of analytical results including veloc...
متن کاملEffectiveness of Bench Top Non-Vacuum Autoclaves on Dental Turbine Chamber Sterilization
Introduction: Dental turbine chamber is a suitable reservoir for living microorganisms, so chamber sterilization is necessary for reducing cross contamination risk. On the other hand, in non-vacuum autoclaves, steam penetration into turbine chamber is doubtful, while they are still in use in dental clinics. In this study, performance of small non-vacuum autoclave in turbine chamber sterilizatio...
متن کاملRelationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter.
PURPOSE To evaluate the relationship between the horizontal ciliary sulcus diameter and anterior chamber diameter measured by 35 MHz ultrasound biomicroscopy (UBM) and the horizontal corneal diameter (white to white [WTW]) measured by scanning-slit topography and to assess the repeatability (intraexaminer difference) of the 2 methods. SETTING Department of Orthoptics and Visual Science, Kitas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SHINKU
سال: 1990
ISSN: 0559-8516,1880-9413
DOI: 10.3131/jvsj.33.738