Validation of an analytical method to quantify serum electrolytes by atomic absorption spectroscopy
نویسندگان
چکیده
منابع مشابه
Indirect Determination of Ascorbic Acid by Atomic Absorption Spectroscopy
A new and simple method followed by atomic absorption spectrometry has been developedfor indirect determination of ascorbic acid (AA). The proposed method was based on the oxidationof AA to dehydroascorbic acid with Cu2+cation(200mgL-1)in an ammonium thiocyanatesolution atpH2.4. AA reduces Cu2+to Cu+followed by the precipitation of Cu+ with SCN-. Then, the excess ofCu2+in the solution was measu...
متن کاملAn Analytical Method Validation for Atomic Absorption Spectrometry Analisys of Total Zinc from Insulin
abstract: An analytical method validation represents a complete investigation of the materials’ properties, following certain steps, being necessary for “proving the fit for purpose of an analytical method”. The validation procedure demonstrate that a defined validation protocol for an analytical method applied to a specified testing material and a defined concentration of the analyt – named an...
متن کاملMeasurement of serum lithium by atomic absorption spectroscopy.
Lithium concentrations in the serum of patients undergoing therapy with lithium salts were measured by atomic absorption spectroscopy. Serum was diluted 10-fold with water. Physiological amounts of sodium and potassium were included in the blank and standard solutions because these cations enhance the lithium signal by 2%. Calcium, magnesium, bicarbonate, sulfate, and phosphate at the concentra...
متن کاملEstimation of gold in serum by atomic absorption spectroscopy.
The therapeutic use of gold compounds is of considerable antiquity, as discussed by Nineham (1); it has been used for the treatment of rheumatoid arthritis since 1927 (2). Treatment in the past has been largely empirical. Until the advent of the atomic absorption spectrophotometer the estimation of gold in biological fluids by classical chemical or other methods was beyond the capability of the...
متن کاملNormal serum calcium levels by atomic absorption spectroscopy.
THE INITIAL STUDIES BY WILLIS (2, 3) and the more recent work of Zettner and Seligson (i) and others (4-7, 9-11) have proven the utility of atomic absorption spectrophotometry (AAS) in the clinical laboratory. However, until very recently there has been very little if any published information dealing with normal serum calcium values by atomic absorption spectrophotometry (11). The primary purp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Universitaria
سال: 2015
ISSN: 2007-9621,0188-6266
DOI: 10.15174/au.2015.747