Validation of an Automated Office Blood Pressure Machine in Pregnant Women According to the AAMI 2013/ISO Protocol

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol.

OBJECTIVE Assessment of the accuracy of the A&D UM-101 mercury-free professional device for auscultatory blood pressure (BP) measurement according to the European Society of Hypertension International Protocol. Further to auscultation, the device has a button to mark readings during deflation. METHODS Fifteen adults were included in phase 1 and another 18 in phase 2. Simultaneous BP measureme...

متن کامل

Comparison of the BPLab® sphygmomanometer for ambulatory blood pressure monitoring with mercury sphygmomanometry in pregnant women: validation study according to the British Hypertension Society protocol

The purpose of this study was to validate the automated BPLab® sphygmomanometer for ambulatory blood pressure monitoring (ABPM) in pregnant women according to Part II of the 1993 British Hypertension Society protocol. Pregnant women attending the antenatal clinic were randomly asked to participate (n=30). The BPLab sphygmomanometer was tested on pregnant women in this study and achieved A/A rat...

متن کامل

Effect of Calcium Supplementation on Blood Pressure of Pregnant Women

The occurrence of pregnancy induced hypertension in low-income young nulliparous women is confirmed in different reports and increase the risk of preeclampsia. More knowledge on the role of nutrients especially calcium demonstrates its major role in regulating blood pressure. Sufficient intake of pregnancy can prevent pregnancy induced hypertension. This study was conducted to evaluate efficacy...

متن کامل

Validation of the ROSSMAX blood pressure measuring monitor according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring Devices in Adults.

BACKGROUND It is now accepted that blood pressure measuring devices should be subjected to an independent evaluation of their accuracy before they are marketed for clinical use. The results of validation of the ROSSMAX Blood Pressure Measuring Monitor for self-measurement according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring Devices ...

متن کامل

Validation of the AGILIS ambulatory blood pressure monitor according to the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults.

BACKGROUND We evaluated the clinical validity of the AGILIS ambulatory blood pressure monitor according to the European Society of Hypertension International Protocol. METHODS The blood pressure (BP) was measured at the same arm by two certified observers using two mercury columns and a double stethoscope, then by the volunteer with the automatic device, these measurements were done seven tim...

متن کامل