Contactless conductivity detector for microchip capillary electrophoresis.

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation chann...

متن کامل

Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection.

The determination of arsenic(III) and arsenic(V), as inorganic arsenite and arsenate, was investigated by CE with capacitively coupled contactless conductivity detection (CE-C(4)D). It was found necessary to determine the two inorganic arsenic species separately employing two different electrolyte systems. Electrolyte solutions consisting of 50 mM CAPS/2 mM L-arginine (Arg) (pH 9.0) and of 45 m...

متن کامل

Simultaneous determination of inorganic cations by capillary ion chromatography with a non-suppressed contactless conductivity detector.

A non-suppressed capillary ion chromatographic method with a laboratory-made packed cation-exchange column (100 mm × 0.32 mm i.d.) was developed for the separation and simultaneous determination of five common inorganic cations (sodium, ammonium, potassium, magnesium and calcium). Cation exchangers were prepared by the reaction of the hydroxyl group on the surface of diol-group bonded silica ge...

متن کامل

Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector.

The impedance of a capacitively coupled contactless conductivity detector (C(4)D) in capillary electrophoresis (CE) was measured by an impedance analysis method. The influence of solution conductivity and capillary dimension on impedance parameters was investigated. Under the experimental conditions used, 86-99.9% of the total impedance of a C(4)D is composed by its imaginary part from the capi...

متن کامل

Characterisation of Crevice and Pit Solution Chemistries Using Capillary Electrophoresis with Contactless Conductivity Detector

The ability to predict structural degradation in-service is often limited by a lack of understanding of the evolving chemical species occurring within a range of different microenvironments associated with corrosion sites. Capillary electrophoresis (CE) is capable of analysing nanolitre solution volumes with widely disparate concentrations of ionic species, thereby producing accurate and reliab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ELECTROPHORESIS

سال: 2016

ISSN: 0173-0835

DOI: 10.1002/elps.201500424