Validation of Fast and Selective Protection Scheme for an LVDC Distribution Network

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Existing DC Protection Solutions on an Active LVDC Distribution Network under Different Fault Conditions

Low Voltage Direct Current (LVDC) distribution is considered as one of the new promising technologies for better integration of distributed generation, and supplying local loads in more efficient way compare to AC systems. However, DC protection is still considered as one of the outstanding challenges that holds back the wide deployment of LVDC in last mile utility applications. Most of existin...

متن کامل

Protecting the last mile – enabling an LVDC distribution network

Traditional distribution power systems are facing numbers of changes. The major aspects that may influence the shape of the changes include: the connection of small scale renewable and advanced distributed energy resources, the deployment of demand side controls, and the supply of more heat and transport demands. But, because distribution systems have been designed and operated with very limite...

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

An Online Free Penetration Multi-Stage Fuse Saving Protection Scheme in Distribution Systems with Photovoltaic Sources

In this paper, a multi-stage protective scheme is proposed to maintain the fuse and reclosers coordination. The proposed method operates online and proportional to the photovoltaic sources penetration rate. In the first step, a non-standard Current - Time - Voltage curve is used for fuse saving. If the new calculated TDS from the first stage is not implementable to the reclosers, the second sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 2017

ISSN: 0885-8977,1937-4208

DOI: 10.1109/tpwrd.2016.2593941