Variable flow and optimization of chiller loading effect on energy saving for screw vapor compression-single effect absorption hybrid chiller plant in hospital mechanical room ‒ case study: Tehran heart hospital

نویسندگان

چکیده

Chiller plants are the most energy consuming system during summer season in residential, commercial and hospital buildings. The highly variable cooling demand of buildings connected to a hybrid chiller plant included absorption vapor compression chillers achieve higher efficiencies is one important issues. Cooling load sharing strategies apply water flow have significant impact on consumption consequently with more productivity environmentally protected. This paper examines behavior pattern that includes combination two air-cooled screw three single effect chillers. In order properly understand consumption, an existing mechanical room Tehran has been studied for five months, its compared optimized model. results indicate sequence function way which they placed circuit partial load, highest importance view point saving also by Applying loading achieved plant.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the energy and exergy analysis of single effect absorption chiller

the first and second laws of thermodynamics have been employed to evaluate energy and exergetic efficiency of the single effect absorption chiller which is used for air conditioning purpose. the performance analysis has been carried out by developing a computer program in ees and modeling the chiller and its components. to evaluate entropy of the water/lithium bromide solution at any point, an ...

متن کامل

the effect of traffic density on the accident externality from driving the case study of tehran

در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...

15 صفحه اول

An Optimized Design of a Single Effect Absorption Solar Chiller for an Energy Consuming Optimized Designed Residential Building

Traditional fossil fuels lead to environmental problems and are also depleting. A significant portion of global energy consumption is due to building’s air conditioning. Nowadays there is a great attention toward renewable and sustainable energy sources to support the buildings energy requirements. In this study, a solar cooling machine was designed for a three-floor residential building under ...

متن کامل

Modeling and optimization of a chiller plant

A data-driven approach is utilized to model a chiller plant that has four chillers, four cooling towers, and two chilled water storage tanks. The chillers have varying energy efficiency. Since the chiller plant model derived from data-driven approach is nonlinear and non-convex, it is not practical to solve it by using the traditional gradient-based optimization algorithm. A two-level intellige...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Mechanics & Industry

سال: 2021

ISSN: ['2257-7750', '2257-7777']

DOI: https://doi.org/10.1051/meca/2021006