Variation of hemodynamic parameters after fluid challenge

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic parameters to guide fluid therapy

The clinical determination of the intravascular volume can be extremely difficult in critically ill and injured patients as well as those undergoing major surgery. This is problematic because fluid loading is considered the first step in the resuscitation of hemodynamically unstable patients. Yet, multiple studies have demonstrated that only approximately 50% of hemodynamically unstable patient...

متن کامل

Hemodynamic Parameters to Guide Fluid Therapy (printer-friendly)

and Introduction Abstract The clinical determination of the intravascular volume can be extremely difficult in critically ill and injured patients as well as those undergoing major surgery. This is problematic as fluid loading is considered the first step in the resuscitation of hemodynamically unstable patients. Yet, multiple studies have demonstrated that only about 50% of hemodynamically uns...

متن کامل

Effects of Ketamine, Fentanyl and Paracetamol on Pain Intensity and Hemodynamic Parameters after Deep Vitrectomy

Background & objectives: The aim of this study was to evaluate the effects of preventive administration of ketamine, fentanyl and paracetamol on pain intensity and hemodynamic parameters after deep vitrectomy. Methods: In this clinical trial, 80 candidates of deep vitrectomy surgery were randomly assigned into 4 groups (1-4) and received 0.5 mg / kg ketamine, 2 μg / kg fentanyl, 10 mg/kg of par...

متن کامل

End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness

BACKGROUND EtCO2 variation has been advocated replacing cardiac output measurements to evaluate fluid responsiveness (FR) during sepsis. The ability of EtCO2 variation after a fluid challenge to detect FR in the context of general anaesthesia has not been investigated. Forty patients were prospectively studied. They underwent general anaesthesia for major surgeries. CO was measured by transoeso...

متن کامل

Systolic pressure variation in hemodynamic monitoring after severe blast injury.

Fluid management in patients following blast injury is a major challenge. Fluid overload can exacerbate pulmonary dysfunction, whereas suboptimal resuscitation may exacerbate tissue damage. In three patients, we compared three methods of assessing volume status: central venous (CVP) and pulmonary artery occlusion (PAOP) pressures, left ventricular end-diastolic area (LVEDA) as measured by trans...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Critical Care

سال: 2008

ISSN: 1364-8535

DOI: 10.1186/cc6311