Verifying monitor unit calculations for tangential whole-breast fields in three-dimensional planning

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verifying monitor unit calculations for tangential whole‐breast fields in three‐dimensional planning

An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. For tangential breast fields, monitor unit differences between primary calculations and second checks are usually larger than considered acceptable at other anatomical sites. A simple model to reconcile the differences between sophisticated and simple algorithms is presented,...

متن کامل

Verifying monitor unit calculations for tangential breast fields

An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. Differences between between sophisticated algorithms using 2.5D or 3D calculations and simpler Monitor unit check algorithms assuming a flat water phantom must be expected. For many anatomical sites such differences are small and of little or no consequence in the context of ...

متن کامل

Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...

متن کامل

Verification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet

Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...

متن کامل

evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

background: we have validated the monitor unit calculations from a commercially available treatment planning system (tps) for three intensity modulated radiotherapy (imrt) planning techniques for tangential breast irradiation by using ionization chamber measurements. materials and methods: treatment plans were generated for forty-two breast patients by a forward planned field in field technique...

متن کامل